Temperature Metrology Laboratory

Temperature Metrology Laboratory is equipped with all advance Temperature Calibrators, Readouts, Reference Thermocouples, Standard Platinum Resistance Thermometers, Humidity Generator and Precision Humidity Transmitters.

Temperature Metrology Laboratory is equipped with all advance Temperature Calibrators, Readouts, Reference Thermocouples, Standard Platinum Resistance Thermometers, Humidity Generator and Precision Humidity Transmitters.

A unique and specially designed Laboratory infrastructure allows maintaining the integrity of ultra accuracy calibrators and sensors. This also simulates the high performance and stability to ensure the best Calibration Measurement Capabilities.

Moderate Air-conditioning system with Auto Fresh Air in-take arrangement, makes the environment free from fumes and smokes induces during high temperature measurement.

This Laboratory is also equipped with NPLs patented Humidity generator, which adds feather to the Laboratories uniqueness and enhances its capability for Thermo-humidity and Hygrometer Calibration with the best accuracy and precision. Laboratory is also equipped with Fix Point Humidity Calibrators, which makes the Humidity measurement capability at par with nationally and internationally competent Laboratories.

Further Temperature Laboratory is shortly procuring the Fluke ‘Super Thermometer’, with Fixed point Temperature Cells. This will take Temperature Laboratory to the new height in Technology and reliability.

Labs at a Glance

  • Temperature Metrology Laboratory
  • Temperature Metrology Laboratory
  • Temperature Metrology Laboratory
  • Temperature Metrology Laboratory
  • Temperature Metrology Laboratory

Major standards Installed in the Laboratory

Sr. No.

Description

Range / L.C.

Stability

1

Ultra Low Temperature Bath (Fluke)

-80°C to 100°C / 0.01°C

± 0.007°C

2

Metrology Dry Well (Fluke)

50°C to 700°C / 0.001°C

± 0.005°C

3

High Temperature Dry Block Furnace

150°C to 1200°C / 0.1°C

± 0.5°C

4

Reference Thermocouple S-Type

0°C to 1400°C

± 0.5°C

5

Standard Platinum Resistance Thermometer

-200°C to 670°C

± 0.01°C

6

High Precision Temperature Readout (FLUKE)

-200°C to 1400°C / 0.001°C & 0.0001°C

± 0.002°C

7

Super DAQ Precision Temperature Scanner (FLUKE)

40 channel, Thermocouples and RTDs
-200°C to 1400°C / 0.01°C & 0.1°C

± 0.05°C

8

Precision Humidity Transmitter

5% to 100% RH / 0.01% RH

± 0.8 %RH

9

Humidity Generator

5% to 95% RH

± 1 %RH